Sysmex CA-660

CA-620

  • Runs main clinically important clotting analyses
  • Easy to use, up to 60 samples/hour
  • Dedicated interface to Sysmex’s online services
  • Colour LCD touch screen and integrated barcode reader
  • Robust analyser that will serve you for years

CA-620 – reliable, robust haemostasis testing

The CA-620 is a compact, fully automated haemostasis analyser. It combines proven and successful characteristics – such as the optical detection technology and the reagent system of its predecessors ‒ with new features. It is great as a primary analyser for routine haemostasis testing in low-volume haemostasis laboratories. Or as a powerful backup instrument in a larger lab. The CA-620 has a solid construction in line with our advanced Silent Design concept, is hardwearing and robust. And with its reliable performance, it will support you day in, day out, for years to come.

Haemostasis

Strong performance, high quality results

Strong performance, high quality results

The CA-620 runs all the main clinically important clotting analyses. This includes basic routine tests such as PT, APTT, Fibrinogen and TT. It also runs specialty tests, such as coagulation factors, Lupus anticoagulant and Protein C activity. The reproducibility of the PT and APTT tests complies with CLSI guidelines. And since we have included an additional washing position, the risk of carry-over is minimised. It delivers results you know you can trust, so you can make right decisions. You can optimise your patient care and gain safety through preoperative screening and therapy monitoring.

Simplifying daily laboratory work

Simplifying daily laboratory work

Thanks to a colour LCD touch screen and an integrated barcode reader, the CA-620 is safe and easy to use. And because sample identification is automated, you can be confident you’re always running the tests that are needed on the right samples. You no longer have to batch samples either, which reduces the time you need to do your tests. Since calibration curves are established through simple steps, we’ve managed to cut your calibration time, while the CA-620’s ease of use really helps minimise the risk of errors.

Maintenance requirements are low so that the system is efficient with little downtime. Integrated reagent cooling increases on-board reagent stability. Thanks to a range of sensor functions, the system is particularly safe to operate.

Advanced software, data handling and networking

Advanced software, data handling and networking

The CA-620 is easy to service thanks to its error log capacity and a new type of memory card. It’s easier to set up and update the analyser, and to back up and restore user data and settings.

Using an optional hand-held 2D barcode reader, you can register data of reagents, standards and controls safely, simply and quickly, free up time for other processes and improve your lab’s productivity. This reagent management system and positive sample recognition will also help you meet the growing regulatory demands with respect to documentation, accreditation and traceability.

The CA-620 can help you and your lab stay one step ahead: via a dedicated interface, you can connect it to SNCS, Sysmex’s online services, which will offer a range of innovative service support processes.

Specifications

Specifications

Detection principles

  • clotting: scattered light detection method

No. of detector channels

  • clotting: 4 channels

Parameters

  • clotting   PT, APTT , Fbg, TT , Coagulation Factor Assays (II, V, VII, Viii, IX, X, XI, XII ), Lupus Anticoagulant (screening and confirmation), Protein C, Batroxobin

Throughput

  • max. 60 tests per hour

Test protocols

  • up to 14 programmable

STAT

  • 1 dedicated position

Sample volumes

  • min. 50 μL (PT, APTT, TT)
  • min. 10 μL (Fbg)
  • min. 5 µL (factor assays)

Reagent capacity

  • 13 positions (4 cooled and 3 dedicated to diluents, buffers or cleaning reagents)

Quality control

  • xbar / L-J control: 6 files at 180 points, 14 parameters

Data storage

  • up to 600 samples / max. 3,000 tests

Interfaces

  • colour LCD touch screen (user interface)
  • built-in thermal printer, prints data and graphics
  • built-in barcode reader for samples and STAT
  • 2D hand-held barcode reader for reagents (ISI, lot#, expiry date), calibrators (assigned value, lot#, expiry date), controls (target/limit, lot#, expiry date), samples/STAT (for sample search) (optional)             
  • SNCS capability (dedicated LAN port)
  • LIS (serial)

Dimensions/weights  main unit                                          

  • w x h x d [mm] / [kg]
  • 566 x 490 x 490 / approx. 42
Contact


Should you have any further questions regarding our product portfolio or associated documentation, please contact us:

segcoagsupport@Sysmex-europe.com

Create Pdf

GROWING YOUR KNOWLEDGE

Growing your knowledge
Visit our Academy
Enjoy our Media Centre
All
  • All
  • Documents
  • Podcast
  • Images
  • Videos
See our collection
Company movie