Sysmex Europe
Menu

Revohem Anti-Xa LRT

Simple and efficient anticoagulant management one reagent for all anti-Xa drug activities

The RevohemTM Anti-Xa LRT method is a liquid, ready-to-use, one-stage chromogenic assay based on the inhibition of a constant, excessive amount of FXa in the presence of endogenous AT.

It is suitable for the quantification of indirect and direct anti-Xa inhibitors, such as heparins (UFH and LMWH) as well as heparin analogues (danaparoid and fondaparinux) and direct oral FXa inhibitors (rivaroxaban, apixaban, edoxaban) through dedicated, calibrators and controls aligned with WHO International Standards, ensuring high specificity and sensitivity. Furthermore, no interference from released heparin-neutralising proteins has been observed with the Revohem Anti-Xa LRT kit, due to the use of dextran sulfate.

Revohem Anti-Xa LRT and associated products are available on Sysmex’ CN- and CS-series.

More details

Heparin anticoagulants (UFH and LMWH) are currently used for many preventive or curative indications. Heparin analogues (fondaparinux and danaparoid) are also used in specific clinical situations as alternative anticoagulant therapy, such as in the occurrence of heparin-induced thrombocytopenia (HIT). Measuring these drug concentrations in patient plasma allows for therapy monitoring and dose adjustments.

To monitor heparins and heparin analogues, an anti-Xa assay is the method of choice over the APTT due to its greater precision and rapidity. Additionally, it boasts more specificity and linearity over a wider measuring range, which reduces the amount of adjustments required during dosage.

Rivaroxaban, apixaban and edoxaban are direct oral anticoagulants (DOACs) that inhibit activated factor X (FXa). They have been increasingly used as first-line agents for eligible patients to prevent recurrent VTE and stroke in those with nonvalvular atrial fibrillation. Since their introduction into the market, the number of indications and direct oral factor Xa inhibitors have continued to grow. Due to their superior pharmacological and clinical profile, therapy monitoring is not required since frequent individual patient dosage adjustments are no longer necessary.

Though monitoring is not a necessity in treated patients, measurements of human plasma may still be required in certain cases, particularly in the event of emergency surgery, suspected overdosage due to renal impairment (bleeding risk) or suspected non-compliance (thrombosis risk).

Following the evolution of the anticoagulant market, the Sysmex portfolio expanded accordingly and will continue to grow alongside the market to ensure that we can always offer complete, universal solutions for laboratory measurement.

 

For further information, please refer to the dedicated Instructions for Use (IFU) or contact your local Sysmex representative.

 

Technical specifications
 
Product name
LIQ
No standing time
Kit presentation
Order reference
Reagent
Revohem Anti-Xa LRT
3 x 3 mL
4 x 5 mL
4 x 7.5 mL
CG217097
AL064127
BU634799
Diluent
Revohem Anti-Xa Diluent
20 mL x 4
AF018369
Heparins
Revohem Heparin Hybrid Calibrator
 
 
5 levels x 4 x 1mL
BQ221064
 
Revohem LMWH Control Plasma
 
 
2 levels x 6 x 1 mL
CE227688
 
Revohem UFH Control Plasma
 
 
2 levels x 6 x 1 mL
AZ296682
Rivaroxaban
Revohem Rivaroxaban Calibrator
 
 
3 levels x 3 x 1 mL
AC222492
 
Revohem Rivaroxaban Control
 
 
2 levels x 6 x 1 mL
BB808578
Apixaban
Revohem Apixaban Calibrator
 
 
3 levels x 3 x 1 mL
AP675507
 
Revohem Apixaban Control
 
 
2 levels x 6 x 1 mL
AY519357
Edoxaban
Revohem Edoxaban Calibrator
 
 
3 levels x 3 x 1 mL
CE077977
 
Revohem Edoxaban Control
 
 
2 levels x 6 x 1 mL
AD713277
Fondaparinux
Revohem Fondaparinux Calibrator
 
 
4 levels x 3 x 1 mL
CW731055
 
Revohem Fondaparinux Control
 
 
2 levels x 6 x 1 mL
BT830756
Danaparoid
Revohem Danaparoid Calibrator
 
 
3 levels x 3 x 1 mL
CE707939
 
Revohem Danaparoid Control
 
 
2 levels x 6 x 1 mL
CJ744965

 
Heparin
(UFH/LMWH)
Rivaroxaban
Apixaban
Edoxaban
Fondaparinux
Danaparoid
Measuring range
0.05–1.80 IU/mL
15–516 ng/mL
20–601 ng/mL
20–499 ng/mL
0.05–1.68 µg/mL
0.05–1.89 U/mL
LoQ/LoD
0.05/0.00
15/14.7
20/19.8
20/15
0.00/0.00
0.00/0.00
Precision
CV ≤10 %
Onboard stability on Sysmex analysers
7 days

Interferences
Heparin
(UFH/LMWH)
Rivaroxaban
Apixaban
Edoxaban
Fondaparinux
Danaparoid
Haemoglobin
300 mg/dL
1000 mg/dL
1000 mg/dL
1000 mg/dL
250 mg/dL
300 mg/dL
Bilirubin (free/Conjugated)
25 mg/dL
60 mg/dL
60 mg/dL
60 mg/dL
45 mg/dL
30 mg/dL
45 mg/dL
30 mg/dL
Triglycerides
875 mg/dL
875 mg/dL
875 mg/dL
875 mg/dL
1000 mg/dL
315 mg/dL

 

To find out more, please contact your local Sysmex representative.

All products listed on this webpage meet IVDR requirements and carry CE 0197 and UKCA conformity markings.

Latest update Dec. 2025

 

Contact us
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Europe SE

Deelböge 19 D

22297 Hamburg

Germany

+49 (40) 527 26 0

+49 (40) 527 26 100

Training

Revohem basic online training - Discover the basics of Revohem reagents and handling procedures on the CN-series in this online training and get started with Revohem products with confidence

For user trainings, please contact your local Sysmex representative.

Explore more

CN track

CN track

Coagulation transportation system

Details
CN-6500/3500

CN-6500/3500

The power of innovation

Details
Copyright © Sysmex Europe SE. All rights reserved.