PATIENT PORTAL

Sysmex is active in a broad spectrum of healthcare areas. In addtion
to information for healthcare professionals we also provide 
applied information for privat individuals seeking assistance in our
areas of expertise. 

At the moment we provide guidance and background info on
breast cancer. We welcome you to visit http://www.breast-cancer-diagnosis.co.uk/

 

 

Please select your country. This will keep you up to date with your country-specific information.

Sysmex UX-2000

UX-2000

  • Automated test strip analysis and
    fluorescence flow cytometry
  • Comprehensive list of parameters
  • Works at the push of a button
  • Standardised, efficient workflow management
    and automation
  • Up to 150 samples/hour

Documents

All
  • All
  • Brochure
Documents

Automated test strip and particle analysis in a single urinalysis device

Our UX-2000 answers a longstanding customer wish for greater convenience and automation in urinalysis. Now, a single device incorporates the two most common testing methods in urinalysis. Dry chemistry test strips, and particle analysis using fluorescence flow cytometry.

At a single push of a button, this bench-top analyser takes on the complete urine screening process. Using criteria that you define in line with your needs. To the highest and which comply to recent regulatory standards. With high clinical utility. And some of the most comprehensive parameters available .

Urinalysis

Detailed information

Detailed information

In the UX-2000, we believe we have addressed all your major challenges in urinalysis: cost, speed, quality, networking and standardisation.

To date, lab staff has always had to run two separate tests: test strips and particle analysis. No longer. Now the UX-2000 offers both test strip analysis for three types of test strip, and particle analysis using Sysmex’s world famous fluorescence flow cytometry plus hydrodynamic focusing, now applied in urinalysis.

You can free up significant time for your lab staff to concentrate on other matters. Choose which type of tests you wish to apply. Test for a vast array of parameters  and eliminate errors associated with the manual testing process. You will also offer the high-quality standardised testing called for by today’s extensive legislation.

At last: two-in-one urinalysis

At last: two-in-one urinalysis

Lab users have been calling for it for years, and we have come up with the solution: a single urinalysis analyser that performs both dry chemistry test strip analyses and particle analysis using fluorescence flow cytometry.

You can now define the testing process applicable for each sample – test strip analysis only, sediment analysis only, or both analyses combined. The job is done at the press of a single button. And you can easily adapt the different workflows to your laboratory needs using settings available to any authorised user.

Just push one button and the job is done

Just push one button and the job is done

Urinalysis used to take up a large amount of lab staff’s precious time – selecting which samples need which; manual test strip testing, reading the results and then entering the results into the database.

No longer. You can now define the testing process for each sample. Then you simply place the samples in racks on the sampler, and press the button. If you want, the device can automatically select a test strip that offers an additional Prot/Crea ratio or one with a microalbumin concentration test. Just place the test strip types of your choice in the dedicated compartments.

Mixing and aspiration are automated with an aspiration volume of just 800µL and defined and automated dilution of 1:4 for sediment analysis and 1:8 for bacterial analysis. Labelling and incubation at optimal temperatures are automatic too. So you know you can count on the results.

Thanks to the high level of standardisation and automation, throughput is quick – up to 150 samples per hour depending on sieve criteria and the sample pool. And importantly – your results are in your database within minutes and you can exclude a possible UTI. Instead of having to wait for hours like you used to.  

Specifications

Specifications

Technologies

  • Dry chemistry teststrip test (CHM)
  • and fluorescence flow cytometry (FCM)

Parameters teststrip part (depending on the type of teststrip)

  • Glucose (9U, 10U and 10K)
  • Protein (9U, 10U and 10K)
  • Bilirubin (9U, 10U and 10K)
  • Urobilinogen (9U, 10U)
  • Blood (9U, 10U and 10K)
  • pH (9U, 10U and 10K)
  • Ketone Bodies (9U, 10U and 10K)
  • WBC (9U, 10U and 10K)
  • Microalbumin (10K)
  • Creatinine (10U and 10K)
  • Microalbumin/Creatinine Ratio (10K)
  • Protein/Creatinine Ratio (10U and 10K)
  • Specific Gravity (transmission
  • refractometry method)
  • Turbidity (reflectivity measurement method)
  • Colour (light-scattering measurement method)

Parameters FCM part

  • Analysis parameters:
  • RBC, WBC, EC, CAST, BACT
  • Research parameters:
  • X’tal, YLC, SRC, Path. CAST, SPERM,
  • MUCUS, Conductivity

Results, scattergrams and histograms

  • Shown in the IPU as individual teststrip and 
    fluorescence flow cytometry results, but also
    as merged results
  • A plausibility check between the results from the
    two different analysis parts is possible.

Profiles ordered
by item rack,
LIS order
or default order


  • Teststrip analysis only (choosing a dedicated feeder is possible) Particle counting and differentiation only (can be performed in manual or sampler mode)

Possible
workflows

  • FCM as a reflex test, triggered by
    criteria based on CHM results
    100% rule: always both analyses
    (CHM and FCM) to be performed

Throughput

 

  • Approx. 150 samples/hour (with 50% particle analyses)

 

STAT function

  • Available for FCM part

 

Sampler unit
capacity

  • Integrated sampler with a capacity for 70 samples in the entry and 60 samples in the exit area

 

Reagent management

  • Integrated into the IPU

 

Data storage

  • Analysis results: 10,000 analyses including
  • scattergrams and histograms
  • QC chart: 24 files (300 points/file)
  • Patient Master: 5,000 items
  • Doctor Master: 100 items
  • Ward Master: 100 items
  • Error log: 3,000 items
  • Audit log: 3,000 items
  • Maintenance history: 3,000 items
  • Reagent replacement history: 3,000 items

 

Dimensions

  • main unit 800(W)x710(D)x720(H)mm

 

Weight main unit

  • Approx. 120kg (with sampler)

 

Interface to LIS

  • SUIT (Sysmex Universal Interface)
  • TCP/IP connection

 

Operative
temperature

  • 15°C to 30°C

 

Operative
humidity

  • 30–60% R.H. (no condensation)

 

Noise

  • Less than 85dB

 

Power
requirement

  • AC 100–240V, 50–60Hz, 400VA max. (main unit plus sampler and built-in barcode reader)

 

 

Video

Video

Contact

Sysmex Europe GmbH

+49 (40) 527 26 0
+49 (40) 527 26 100
info@sysmex-europe.com
Bornbarch 1
22848 Norderstedt
Germany

Create Pdf

SYSMEX SOLUTION PROVISION

Optimising your laboratory
Enjoy our Media Centre
All
  • All
  • Documents
  • Podcast
  • Images
  • Videos
Explore our microsite
See our collection