XN-1500

  • Fully integrated slide maker & stainer with small footprint
  • Flexible throughput of smear preparation depending on the workload
  • Short turnaround times
  • Less biohazard procedures
  • Optional integration of digital imaging module

XN-1500 – Count. Smear. Stain. All-in-one haematology

For the first time, we have combined our market-leading XN-Series analyser with a brand-new slide maker/stainer in an all-in-one workstation. Should an analysis result lead to a smear, it is performed without manual intervention. The result? Consistent smears with a beautiful cell monolayer that make further microscopic diagnostics as easy and powerful as possible. Add a DI-60, our digital imaging analyser, and microscopic analysis can be performed automatically, too.

Reflex testing occurs within the same loop, and so does the smear preparation when it is needed. Like extended measurements, smears are only initiated if they offer additional diagnostic value. The analysis profile is extended automatically to include smear-making and staining, but you may also order this up front, for instance with known special samples.

XN-1500 specifications

XN-1500 specifications

Measurement principles

WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin

Aspiration volume    

XN:
88 µL in whole blood (WB) mode and body fluid (BF) mode

SP-50:
70 µL for smear preparation in auto mode,
38 µL for smear preparation in manual mode

Throughput  

XN:
up to 100 samples/h in whole blood (WB) mode,
up to 40 samples/h in body fluid (BF) mode

SP-50:
up to 30 slides/h in standard mode,
up to 75 slides/h with the optional high-throughput licence

Quality control materialXN Check (three levels) and XN Check BF (two levels)

Parameters

XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)

RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)

PLT-F, IPF, IPF#

With WPC (optional)

Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence

HPC%, HPC#

Body Fluids with XN-BF (optional)

WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#