SARS-CoV-2 Ag Diagnostic Test kit (Colloidal Gold)

 

 

More details

Reliable and cost-effective SARS CoV-2 antigen rapid test

The easy-to-use test, utilising the standard lateral flow test cassette for the detection of SARS-CoV-2 virus antigen, provides reliable visual results after 10 minutes. The test kit is based on colloidal gold immunoassay technology.   

It is an Ideal solution for fast and qualitative results in patients with onset of symptoms between 0-7 days

The collection of the specimen, using either a naso-/oropharyngeal sample or a saliva swab is very simple.  

The sample is applied to the buffer tube and, afterwards, the prepared solution will be dripped onto the test strip.

After the incubation time, results are read manually by the operator.

The test was evaluated by Paul-Ehrlich-Institute (Germany)

 

Test interpretation

Technical specifications
Technology Lateral flow sandwich immunoassay
Sample type Saliva, naso-/oropharyngeal swab
Buffer volume

26 x 500 μL
(ready-to-use buffer and mixing tube)

Sample volume 100 μL (3 drops)/test

Sensitivity
(supplier information)

Naso-/oropharyngeal sample:
87.0 % (RT-PCR CT value ≤ 36);
95.15 % (≤ 7 days symptom onset)
Saliva sample:
90.45% % (RT-PCR CT value ≤ 36);
95.51%  (≤ 7 days symptom onset)

Specificity
(supplier information)

Naso-/oropharyngeal sample: 99.12%
Saliva sample: 99.45%
Packaging specification 25 tests/kit

 

for more details please refer to the IFU

Contact us
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Europe SE

Bornbarch 1

22848 Norderstedt

Germany

+49 (40) 527 26 0

+49 (40) 527 26 100

Documents

Product documents

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

Dear customer,

The following list of research study publications is provided exclusively for scientific purposes. By clicking "Confirm" below, you accept the following terms:

- The studies may relate to the diagnostic use of the analytical parameters offered by Sysmex instruments. The diagnostic use is not validated by Sysmex and is therefore not in the scope of the Intended Purpose of the instruments. Details on the Intended Use can be found in the Sysmex Instructions For Use.
- Summaries of the study results are provided for convenience only and are not intended to convey any views of Sysmex on the study or the products used therein.
- Sysmex cannot be held liable for the accuracy of the study results or the summaries of the study results.
- The information provided in the literature list is intended only for health care professionals.

This site is for 'Professionals' only. You are not authorised to view this page.

Copyright © Sysmex Europe SE. All rights reserved.